• Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device
  • Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device
  • Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device
  • Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device
  • Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device
  • Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device

Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCB
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Our Advantages
  • Certificates
Overview

Basic Info.

Model NO.
ZYB1
Poles Number
2
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Under and Over Voltage Protection
Certification
CE
Rated Operating Current
10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rated Operating Voltage
AC230V
Electrical Life
> 100,000 Times
Frequency
50Hz
Display
Indicator
Transport Package
Standard Export Packing
Specification
77*36*45mm
Trademark
ZOLL
Origin
China
HS Code
8536500000
Production Capacity
10000PCS/Month

Product Description

 

Our Advantages

Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device

1.General Introduction

The automatic over-voltage and under-voltage delay protector is a new generation product developed by our company according to market needs.  The protector is reasonably designed and assembled with imported components and domestic famous-brand components. It adopts advanced manufacturing methods. The product can quickly and reliably cut off the power supply under high-voltage shock and under-voltage conditions to protect household appliances. When the voltage returns to the normal value, the circuit can be automatically turned on and the power supply will be restored after delay, which can effectively protect the electrical appliances from the impact of the power supply momentarily. All functions are fully automated with no special person operation is required. Two-color light-emitting diodes are selected. The power indicator is green and the protection indicator is red.

 
2. Main technical parameters
 
Specification Rated Current(In) Rared Voltage(V) Rated Frequency(Hz) Overvoltage Start Value(V) Normal Voltage Start Value(V) Undervoltage Start Value(V)
Two-phase overvoltage 32,40,50,63,80 230VAC 50 275±5 240-260 175±5
Three-phase overvoltage with lack of phase/ Three-phase four line overvoltage with lack of phase 380VAC 460±15 420-440 300±15
 
Specification Normal Voltage Start Value(V) Overvoltage and Undervoltage start time(S)  Power Consumption(W) Electrical Machinery Life
Two-phase overvoltage 190±5 ≤60S <1 >100000 times
Three-phase overvoltage with lack of phase/ Three-phase four line overvoltage with lack of phase 335±10 <2

3. Installation and Dimension

Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection DeviceZoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device
Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device
4. Precautions

4.1 When the power supply of the product is normal, the first time the input terminal is connected to the power supply requires a delay time of less than 1 minute before the product is powered on.   
4.2 When the protector enters the protection state when the voltage is abnormal, the internal relay has only one set of contacts to cut off the live line. Installation must be correctly connected to the neutral line N and the phase line and the phase line L, otherwise the load is live.
4.3 After the product is connected to the power supply, do not touch the live parts to avoid electric shock. 
4.4 Be sure to tighten the terminal screws when wiring, otherwise the terminal will trigger heat due to poor contact and cause damage to the product or cause other accidents.


5. Normal usage conditions

5.1 The ambient temperature does not exceed +50 degrees and not less than -40 degrees.
5.2 The altitude of the installation site does not exceed 2000 meters
5.3 Humidity: not more than 85%
5.4 Pollution degree 3
5.5 This product is a TH35mm rail


6. Ordering instructions

Need to explain the product model, product protection current specifications, voltage level, quantity, if there are special requirements, pls indicate otherwise

 

 

Certificates

Zoii 40A 63A Resttable Over-Voltage Protector Overvoltage Undervoltage Protection Device




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.